Skip image slider
LTDO210 316L optical dissolved oxygen sensor for continuous online water monitoring
LTDO210 316L optical dissolved oxygen sensor for continuous online water monitoring
LTDO210 RS485 fluorescent dissolved oxygen sensor with 316L stainless steel housing
LTDO210 optical dissolved oxygen sensor replaceable fluorescence sensing cap detail
LTDO210 industrial dissolved oxygen probe cable and stainless steel connection detail

LTDO210 316L Optical Dissolved Oxygen Sensor with RS485

316L optical DO sensor with RS485 Modbus, automatic compensation and low-maintenance fluorescence technology for continuous water monitoring.

• Dynamic fluorescence quenching — no electrolyte consumption and no oxygen consumption during measurement.
• RS485 Modbus RTU output for PLC, controller and SCADA integration.
• Built-in temperature, pressure and salinity compensation.
• 316L stainless steel housing with passivation treatment and IP68 protection.
• No polarization or warm-up required; replaceable fluorescence cap for easier maintenance.

Optical Dissolved Oxygen Sensor Description

The LTDO210 316L Optical Dissolved Oxygen Sensor with RS485 is designed for continuous DO monitoring in wastewater, aquaculture, surface water, and industrial water systems. It uses dynamic fluorescence quenching technology, so measurement does not consume oxygen or require electrolyte replacement. Built-in temperature, pressure, and salinity compensation support stable field measurement, while RS485 Modbus RTU enables easy integration with PLC, SCADA, and water quality controllers. The passivated 316L stainless steel housing, IP68 protection, replaceable fluorescence cap, and low-power design make it a durable, low-maintenance option for long-term online monitoring projects.

LTDO210 Optical DO Sensor Technical Data

Measurement Principle Dynamic fluorescence quenching
Dissolved Oxygen Range 0–20 mg/L
Saturation Range 0–200%
DO Accuracy ±2% F.S.
DO Resolution 0.01 mg/L
DO Response Time 40 seconds T90
Calibration Method Two-point calibration
Temperature Accuracy ±0.5°C
Temperature Resolution 0.1°C
Working Temperature 0–45°C
Temperature Compensation Automatic, Pt1000
Temperature Response Time 30 seconds T90
Pressure Compensation Built-in
Salinity Compensation Built-in
Output Signal RS485
Communication Protocol Modbus RTU
Power Supply 12 or 24 VDC ±10%
Current Consumption 10 mA
Working Pressure <0.2 MPa
Protection Rating IP68
Maximum Water Depth 20 m
Housing Material 316L stainless steel
Surface Treatment Corrosion-resistant passivation
Standard Cable Length 10 m
Cable Customization Available
Fluorescence Cap Replaceable
Listed Sensor Service Life 1 year or more

LTDO210 Dissolved Oxygen Sensor Applications

• Wastewater Treatment: Continuous DO monitoring in aeration tanks and biological treatment processes.
• Aquaculture & RAS: Monitors dissolved oxygen in ponds, tanks and recirculating aquaculture systems.
• Surface Water Monitoring: Suitable for rivers, lakes, reservoirs and environmental monitoring stations.
• Industrial Water Systems: RS485 Modbus supports integration with PLC, controllers and OEM monitoring equipment.

FAQ
Does the LTDO210 require electrolyte?

No. The LTDO210 uses optical fluorescence quenching technology and does not require electrolyte for dissolved oxygen measurement.

Does the sensor consume oxygen during measurement?

No. Optical dissolved oxygen measurement does not consume oxygen from the sample.

Does the LTDO210 need polarization before use?

No. Unlike polarographic dissolved oxygen electrodes, it does not require electrode polarization or a long warm-up period.

What is the measurement range?

The dissolved oxygen measurement range is 0–20 mg/L, with a saturation range of 0–200%.

What communication does the LTDO210 support?

The sensor provides RS485 digital output and supports Modbus RTU communication.

Does it include automatic compensation?

Yes. The sensor includes automatic temperature compensation using Pt1000, built-in pressure compensation and salinity compensation.

What is the standard cable length?

The standard cable is 10 meters, with customized cable lengths available for project requirements.

What is the sensor housing material?

This LTDO210 version uses a 316L stainless steel housing with surface passivation treatment.

Request an LTDO210 Configuration & Quote

Looking for an optical dissolved oxygen sensor for wastewater, aquaculture, surface water or OEM water-quality monitoring equipment?

Send LOOTEST your application, DO range, water temperature, installation method, cable length and communication requirements. We can help confirm whether the LTDO210 configuration is suitable for your project.

Extra Information

Optical Measurement & Low Maintenance

The LTDO210 uses fluorescence quenching technology, so it does not require electrolyte and does not consume oxygen during measurement. No electrode polarization or warm-up is required, and the fluorescence cap is replaceable for easier field maintenance.

316L Housing & Digital Integration

The passivated 316L stainless steel body provides a robust structure for online installation. RS485 Modbus RTU output allows direct integration with compatible PLC, SCADA, controllers and OEM monitoring systems.

Get a Quote for LTDO210 Optical DO Sensor

Send us your application, cable length and integration requirements for configuration support and a project quote.

Related Products

Related News

If you ask, “Which dissolved oxygen sensor is better—optical or membrane?” the honest answer is: better for what? A wastewater […]

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)
If you have any questions, please do not hesitate to contatct with us.
about us1